Column Load Calculator
Work out column load instantly with clear inputs, formula shown and shareable results.
About Column Load Calculator
Column load accumulates down the building: the tributary area, the floor area whose load finds its way to that column, multiplied by the load intensity and the number of floors above. The service total is used for foundation bearing checks, while the factored combination 1.2 dead plus 1.6 live is used to design the column itself.
Formulas
Axial load
Load = tributary area x floors x (dead + live)
Factored
Design load = 1.2 x dead + 1.6 x live
Worked example
With the default values below, Column Load Calculator returns Factored design load of 1,080.0. Change any input above and every figure here is recalculated in your browser.
Inputs used
- Tributary floor area per storeyminimum 0.1 m²
- 25 m²
- Number of floors carriedminimum 1
- 4
- Dead loadminimum 0.1 kPa
- 5 kPa
- Live loadminimum 0 kPa
- 3 kPa
Results
- Factored design load
- 1,080.0 kN
- Service load
- 800.0 kN
- Dead load contribution
- 500.0 kN
- Live load contribution
- 300.0 kN
Step by step
- 1Values used
- 2Axial load
- 3Factored
- 4Factored design load= 1,080.0 kN
- 5Service load= 800.0 kN
- 6Dead load contribution= 500.0 kN
- 7Live load contribution= 300.0 kN
Assumptions and limits
- The result is derived only from the 4 inputs listed above. Anything not among them is not part of the calculation.
- In particular, this calculator does not take inflation, tax or compounding frequency into account.
- Figures are rounded for display to 1 decimal place, so totals built from several rounded parts can differ slightly from the unrounded arithmetic.
- Preliminary estimate only. Column design loads and combinations must be established by a qualified structural engineer to the governing code.
How these calculators are built and tested is described on the Methodology page. If a figure looks wrong, please report it.
Preliminary estimate only. Column design loads and combinations must be established by a qualified structural engineer to the governing code.
Frequently Asked Questions
How is the Column Load figure worked out?
Load = tributary area x floors x (dead + live). Column load accumulates down the building: the tributary area, the floor area whose load finds its way to that column, multiplied by the load intensity and the number of floors above.
Can live load be reduced for many floors?
Yes. Codes allow a reduction because it is improbable that every floor is fully loaded at once. The reduction grows with the number of floors and the tributary area.
What values do I need to enter?
This calculator takes 4 inputs: Tributary floor area per storey, Number of floors carried, Dead load, Live load. The pre-filled defaults are a realistic worked example — replace them with your own site or project figures.
Related Calculators
You might also need
- Beam Load CalculatorAlso in Construction & Civil Engineering
- Dead Load CalculatorAlso in Construction & Civil Engineering
- Live Load CalculatorAlso in Construction & Civil Engineering
- Load Combination CalculatorAlso in Construction & Civil Engineering
- Occupancy Load CalculatorAlso in Construction & Civil Engineering
- Seismic Load CalculatorAlso in Construction & Civil Engineering