Digester Volume Calculator
Work out digester volume instantly with clear inputs, formula shown and shareable results.
About Digester Volume Calculator
Anaerobic digesters are sized on the greater of two criteria: hydraulic retention time, 15-25 days for mesophilic digestion, and volumetric volatile solids loading, generally 1.6-3.2 kg VS/m3/day. Thin sludge is governed by retention time; well-thickened sludge is governed by loading.
Formulas
Retention time basis
Volume = feed volume x retention time
Loading basis
Volume = volatile solids load / maximum volumetric loading
Worked example
With the default values below, Digester Volume Calculator returns Digester Volume Required of 1,200.00. Change any input above and every figure here is recalculated in your browser.
Inputs used
- Sludge Feed Volumeminimum 0 m3/day
- 60 m3/day
- Hydraulic Retention Timeminimum 0 days
- 20 days
- Volatile Solids Loadminimum 0 kg VS/day
- 1,800 kg VS/day
- Maximum Volumetric Loadingminimum 0 kg VS/m3/day
- 2 kg VS/m3/day
Results
- Digester Volume Required
- 1,200.00
- Volume From Retention Time
- 1,200.00
- Volume From Loading Limit
- 900.00
- Actual Volumetric Loading
- 1.5000
Step by step
- 1Values used
- 2Retention time basis
- 3Loading basis
- 4Digester Volume Required= 1,200.00
- 5Volume From Retention Time= 1,200.00
- 6Volume From Loading Limit= 900.00
- 7Actual Volumetric Loading= 1.5000
Assumptions and limits
- The result is derived only from the 4 inputs listed above. Anything not among them is not part of the calculation.
- In particular, this calculator does not take inflation, tax or compounding frequency into account.
- Figures are rounded for display to 4 decimal places, so totals built from several rounded parts can differ slightly from the unrounded arithmetic.
- Digester gas is flammable and asphyxiating, and digesters are confined spaces. Design and operation must comply with gas safety and confined space regulations.
How these calculators are built and tested is described on the Methodology page. If a figure looks wrong, please report it.
Digester gas is flammable and asphyxiating, and digesters are confined spaces. Design and operation must comply with gas safety and confined space regulations.
Frequently Asked Questions
Why does thickening the feed help?
It reduces feed volume for the same solids, so the retention time criterion needs less volume. Digesters fed thin sludge waste capacity heating and holding water.
What limits volumetric loading?
Volatile fatty acid accumulation and ammonia inhibition. Overloading drops pH and stalls methanogenesis, which can take weeks to recover.
Related Calculators
- Aeration Tank Volume Calculator
- Backwash Water Volume Calculator
- Composting Windrow Volume Calculator
- E Waste Volume Calculator
- Grey Water Reuse Volume Calculator
- MBBR Media Volume Calculator
- RO Reject Volume Calculator
- Sludge Volume Index Calculator
- Water Softener Resin Volume Calculator
- Activated Carbon Dose Calculator
You might also need
- E Waste Volume CalculatorAlso in Water, Waste & Environmental Engineering
- RO Reject Volume CalculatorAlso in Water, Waste & Environmental Engineering
- Aeration Tank Volume CalculatorAlso in Water, Waste & Environmental Engineering
- Backwash Water Volume CalculatorAlso in Water, Waste & Environmental Engineering
- Composting Windrow Volume CalculatorAlso in Water, Waste & Environmental Engineering
- MBBR Media Volume CalculatorAlso in Water, Waste & Environmental Engineering