Rainwater Tank Size
Free Rainwater Tank Size calculator with clear step-by-step results.
About Rainwater Tank Size
Two numbers size a rainwater system: annual yield, which is roof plan area times rainfall times a runoff coefficient, and storage, which is set by the longest dry period you need to ride out. A tank larger than the dry-period requirement adds cost without adding usable water.
Formulas
Annual yield
Litres = roof plan area m2 x rainfall mm x runoff coefficient, less first-flush losses
Storage requirement
Litres = daily demand x longest dry period in days
Worked example
With the default values below, Rainwater Tank Size returns Recommended tank capacity of 5,400. Change any input above and every figure here is recalculated in your browser.
Inputs used
- Roof catchment area (plan)minimum 1 m2
- 120 m2
- Annual rainfallminimum 10 mm
- 750 mm
- Runoff coefficientaccepts 0.2–1
- 0.85
- Daily demandminimum 0 L
- 180 L
- Longest expected dry periodaccepts 1–365
- 30
- First flush divertedaccepts 0–5 mm
- 0.5 mm
Results
- Recommended tank capacity
- 5,400 L
- Water harvestable per year
- 72,900 L
- Annual demand
- 65,700 L
- Share of demand rainwater can meet
- 100.0% %
Step by step
- 1Values used
- 2Annual yield
- 3Storage requirement
- 4Recommended tank capacity= 5,400 L
- 5Water harvestable per year= 72,900 L
- 6Annual demand= 65,700 L
- 7Share of demand rainwater can meet= 100.0 %
Assumptions and limits
- The result is derived only from the 6 inputs listed above. Anything not among them is not part of the calculation.
- In particular, this calculator does not take inflation, tax or fees or charges into account.
- Figures are rounded for display to 1 decimal place, so totals built from several rounded parts can differ slightly from the unrounded arithmetic.
How these calculators are built and tested is described on the Methodology page. If a figure looks wrong, please report it.
Frequently Asked Questions
Why use plan area rather than sloped area?
Rain falls vertically, so the catchment is the horizontal footprint. A steep roof catches no more rain than its plan area regardless of how much surface it has.
What runoff coefficient should I use?
Around 0.9 for metal roofing, 0.8-0.85 for tile and 0.7 or less for porous surfaces. Losses come from wetting, evaporation and gutter overshoot.
Related Calculators
You might also need
- bath water usageAlso in Environmental & Sustainability
- Battery Storage CalculatorAlso in Environmental & Sustainability
- Car Emissions CalculatorAlso in Environmental & Sustainability
- Compost ApplicationAlso in Environmental & Sustainability
- Compost CalculatorAlso in Environmental & Sustainability
- Crop Water RequirementAlso in Environmental & Sustainability