SBR Cycle Time Calculator
Work out sbr cycle time instantly with clear inputs, formula shown and shareable results.
About SBR Cycle Time Calculator
A sequencing batch reactor cycles through fill, react, settle, decant and idle in one tank. Total cycle time determines how many batches a day each tank handles and therefore the volume it can treat. Typical cycles are 4-8 hours, with the react phase split into anoxic and aerobic sub-phases for nutrient removal.
Formulas
Cycle time
Cycle = fill + react + settle + decant and idle
Throughput
Cycles per day = 1440 / cycle time in minutes
Worked example
With the default values below, SBR Cycle Time Calculator returns Total Cycle Time of 270.0. Change any input above and every figure here is recalculated in your browser.
Inputs used
- Fill Timeminimum 0 minutes
- 60 minutes
- React Timeminimum 0 minutes
- 120 minutes
- Settle Timeminimum 0 minutes
- 45 minutes
- Decant And Idle Timeminimum 0 minutes
- 45 minutes
Results
- Total Cycle Time
- 270.0
- Cycles Per Day
- 5.333
- React Phase Share
- 44.444%
- Aerated Share Of Cycle
- 55.556%
Step by step
- 1Values used
- 2Cycle time
- 3Throughput
- 4Total Cycle Time= 270.0
- 5Cycles Per Day= 5.333
- 6React Phase Share= 44.444
- 7Aerated Share Of Cycle= 55.556
Assumptions and limits
- The result is derived only from the 4 inputs listed above. Anything not among them is not part of the calculation.
- In particular, this calculator does not take inflation, tax, fees or charges or compounding frequency into account.
- Figures are rounded for display to 3 decimal places, so totals built from several rounded parts can differ slightly from the unrounded arithmetic.
How these calculators are built and tested is described on the Methodology page. If a figure looks wrong, please report it.
Frequently Asked Questions
How many tanks are needed?
At least two so one can accept flow while the other settles and decants, unless upstream balancing storage is provided. Three or more gives smoother operation and redundancy.
Why is settle time critical?
Decanting must draw clarified supernatant without disturbing the blanket. Insufficient settle time carries solids over; excessive settle time wastes cycle capacity and can trigger denitrification and rising sludge.
Related Calculators
- Detention Time Calculator
- Life Cycle Assessment Impact Calculator
- Activated Carbon Dose Calculator
- Aeration Tank Volume Calculator
- Air Emission Stack Height Calculator
- Alum Dose For Coagulation Calculator
- Ambient Concentration Estimate Calculator
- Backwash Water Volume Calculator
- Baghouse Filter Area Calculator
- Bin Capacity Planning Calculator
You might also need
- Detention Time CalculatorAlso in Water, Waste & Environmental Engineering
- E Waste Volume CalculatorAlso in Water, Waste & Environmental Engineering
- Life Cycle Assessment Impact CalculatorAlso in Water, Waste & Environmental Engineering
- BOD Load CalculatorAlso in Water, Waste & Environmental Engineering
- Chlorine Residual CalculatorAlso in Water, Waste & Environmental Engineering
- COD Load CalculatorAlso in Water, Waste & Environmental Engineering