BTU Calculator

Size heating and cooling BTUs for a room's volume, climate and insulation quality.

Inputs

ft
ft
ft

Each additional person adds ~600 BTU/h cooling load.

Cooling Load

5,250BTU/h

Heating Load

5,063BTU/h

Suggested AC Tonnage

0.5ton

Next standard unit size at or above the calculated requirement.

Exact Tonnage Required

0.44ton

Room Area

180sq ft

Room Volume

1,620cu ft

Step by step

  1. Room area

    15 ft × 12 ft

    = 180 sq ft

  2. Ceiling height factor

    9 ft ÷ 8 ft

    = 1.125

  3. Cooling base load

    180 sq ft × 20 BTU/sq ft

    = 3600 BTU

  4. Apply climate × insulation × sun × height factors

    × 1 × 1 × 1 × 1.125

    = 4050 BTU

  5. Occupant load (cooling)

    2 × 600 BTU

    = 1200 BTU

  6. Total cooling BTU

    = 5,250 BTU/h

  7. AC tonnage required

    5,250 ÷ 12,000

    = 0.44 tons → suggest 0.5 ton unit

How it works

Heating and cooling loads are calculated from the room's floor area using the industry rule-of-thumb of 20 BTU/sq ft for cooling and 25 BTU/sq ft for heating. Three multipliers adjust for climate severity, insulation quality, and sun exposure. Rooms taller than 8 feet have a proportionally higher load. Each occupant adds approximately 600 BTU/h to the cooling load. The result is converted to AC tonnage (12,000 BTU/h = 1 ton) and the next available standard unit size is recommended.

Formulas

Cooling BTU

Cooling BTU = area × 20 × climate × insulation × sun × (height/8) + occupants × 600

Tonnage

Tonnage = Cooling BTU ÷ 12,000

Frequently Asked Questions

What is a BTU?

BTU stands for British Thermal Unit — the amount of heat needed to raise one pound of water by 1°F. HVAC systems are rated in BTU/h (how many BTUs they move per hour).

What is an AC ton?

1 ton of air conditioning = 12,000 BTU/h. The term originates from the cooling power of melting one ton of ice in 24 hours.

Is this calculation accurate enough to buy a unit?

The rule-of-thumb method is sufficient for single-room sizing. For a whole house, a licensed HVAC contractor should perform a Manual J calculation that accounts for local design temperatures, window areas, duct losses and other factors.

Should I size up or down when the result falls between standard sizes?

Always round up for cooling — an undersized unit runs constantly and never achieves setpoint. For heating, rounding up is also safer. The calculator suggests the next standard size above the calculated load.