Buck Converter Duty Cycle Calculator
Work out buck converter duty cycle instantly with clear inputs, formula shown and shareable results.
About Buck Converter Duty Cycle Calculator
In continuous conduction a buck converter's duty cycle is simply Vout/Vin, independent of load. Inductor value follows from the allowed ripple: L = (Vin - Vout) x D / (dI x f), so higher switching frequency permits a smaller inductor for the same ripple.
Formula
Buck converter
D = Vout / Vin; L = (Vin - Vout) x D / (delta_I x fsw)
Worked example
With the default values below, Buck Converter Duty Cycle Calculator returns Duty cycle of 20.833%. Change any input above and every figure here is recalculated in your browser.
Inputs used
- Input voltage
- 24 V
- Output voltage
- 5 V
- Switching frequency
- 300 kHz
- Inductor ripple current
- 30 %
Results
- Duty cycle
- 20.833% %
- Switch on time
- 0.69 µs
- Suggested inductance for 1 A output
- 43.98 µH
- Ideal duty ratio
- 0.20833
Step by step
- 1Values used
- 2Buck converter
- 3Duty cycle= 20.833 %
- 4Switch on time= 0.69 µs
- 5Suggested inductance for 1 A output= 43.98 µH
- 6Ideal duty ratio= 0.20833
Assumptions and limits
- The result is derived only from the 4 inputs listed above. Anything not among them is not part of the calculation.
- In particular, this calculator does not take inflation, tax or fees or charges into account.
- Figures are rounded for display to 5 decimal places, so totals built from several rounded parts can differ slightly from the unrounded arithmetic.
- Electrical results are planning estimates only. Verify against the applicable wiring rules (IEC 60364, BS 7671, NEC or local code) and have all installation work designed and checked by a qualified electrician.
How these calculators are built and tested is described on the Methodology page. If a figure looks wrong, please report it.
Electrical results are planning estimates only. Verify against the applicable wiring rules (IEC 60364, BS 7671, NEC or local code) and have all installation work designed and checked by a qualified electrician.
Frequently Asked Questions
Does duty cycle change with load?
Not in continuous conduction mode. In discontinuous mode at light load it does, which is why light-load regulation behaves differently.
What ripple should I design for?
20-40% of maximum output current is the usual compromise between inductor size and output capacitor ripple.
Related Calculators
- Boost Converter Duty Cycle Calculator
- PWM Duty Cycle Calculator
- 555 Timer Astable Calculator
- 555 Timer Monostable Calculator
- Amp Hours To Watt Hours Calculator
- Amplifier Gain (dB) Calculator
- Antenna Length Calculator
- Bandwidth Of A Filter Calculator
- Battery Bank Sizing Calculator
- Battery Capacity (Ah) Calculator
You might also need
- Boost Converter Duty Cycle CalculatorAlso in Electrical & Electronics
- PWM Duty Cycle CalculatorAlso in Electrical & Electronics
- Capacitance CalculatorAlso in Electrical & Electronics
- Inductance CalculatorAlso in Electrical & Electronics
- VSWR CalculatorAlso in Electrical & Electronics
- Amplifier Gain (dB) CalculatorAlso in Electrical & Electronics