Dilution Factor For Discharge Calculator
Work out dilution factor for discharge instantly with clear inputs, formula shown and shareable results.
About Dilution Factor For Discharge Calculator
The fully mixed concentration downstream is the flow-weighted average of effluent and river. Dilution factor is total flow divided by effluent flow. Consents are usually set against the low-flow condition — commonly the 95th percentile exceedance flow — because that is when dilution is least and the risk greatest.
Formulas
Mass balance mixing
C_mixed = (Q_effluent x C_effluent + Q_river x C_background) / (Q_effluent + Q_river)
Dilution factor
DF = (Q_effluent + Q_river) / Q_effluent
Worked example
With the default values below, Dilution Factor For Discharge Calculator returns Fully Mixed Concentration of 2.0266. Change any input above and every figure here is recalculated in your browser.
Inputs used
- Effluent Flowminimum 0 m3/day
- 5,000 m3/day
- Receiving Water Flowminimum 0 m3/s
- 50 m3/s
- Effluent Concentrationminimum 0 mg/L
- 25 mg/L
- Background River Concentrationminimum 0 mg/L
- 2 mg/L
Results
- Fully Mixed Concentration
- 2.0266
- Dilution Factor
- 865.000
- Increase Above Background
- 0.0266
- Effluent Flow In Cumecs
- 0.057870
Step by step
- 1Values used
- 2Mass balance mixing
- 3Dilution factor
- 4Fully Mixed Concentration= 2.0266
- 5Dilution Factor= 865.000
- 6Increase Above Background= 0.0266
- 7Effluent Flow In Cumecs= 0.057870
Assumptions and limits
- The result is derived only from the 4 inputs listed above. Anything not among them is not part of the calculation.
- In particular, this calculator does not take inflation, tax, fees or charges or compounding frequency into account.
- Figures are rounded for display to 6 decimal places, so totals built from several rounded parts can differ slightly from the unrounded arithmetic.
- Discharge impact assessment must use the statutory low-flow condition and environmental quality standards specified by the regulator.
How these calculators are built and tested is described on the Methodology page. If a figure looks wrong, please report it.
Discharge impact assessment must use the statutory low-flow condition and environmental quality standards specified by the regulator.
Frequently Asked Questions
Which river flow should be used?
The statutory low flow, typically Q95 — the flow exceeded 95% of the time. Using average flow overstates dilution and produces consents that fail in summer.
Does full mixing happen immediately?
No. There is a near-field mixing zone downstream of the outfall where concentrations are much higher. Environmental quality standards may have to be met at the edge of a defined mixing zone.
Related Calculators
- Alum Dose For Coagulation Calculator
- Chlorine Dose For Water Calculator
- Effluent Discharge Standard Check Calculator
- Lime Dose For Softening Calculator
- Oxygen Requirement For Aeration Calculator
- Peak Water Demand Factor Calculator
- UV Dose For Disinfection Calculator
- Water Demand For Population Calculator
- Activated Carbon Dose Calculator
- Aeration Tank Volume Calculator
You might also need
- UV Dose For Disinfection CalculatorAlso in Water, Waste & Environmental Engineering
- E Waste Volume CalculatorAlso in Water, Waste & Environmental Engineering
- Alum Dose For Coagulation CalculatorAlso in Water, Waste & Environmental Engineering
- Chlorine Dose For Water CalculatorAlso in Water, Waste & Environmental Engineering
- Effluent Discharge Standard Check CalculatorAlso in Water, Waste & Environmental Engineering
- Lime Dose For Softening CalculatorAlso in Water, Waste & Environmental Engineering