Peak Water Demand Factor Calculator
Work out peak water demand factor instantly with clear inputs, formula shown and shareable results.
About Peak Water Demand Factor Calculator
Distribution networks are sized on peak hour flow, which is average demand multiplied by a maximum day factor of 1.3-1.8 and a peak hour factor of 1.5-3.0. Small communities show much sharper peaks; Harmon's formula, 1 + 14/(4 + sqrt(population in thousands)), captures that population-dependent damping.
Formulas
Peak flows
Maximum day = average x max day factor; peak hour = average x max day factor x peak hour factor
Harmon formula
Peak factor = 1 + 14 / (4 + sqrt(population / 1000))
Worked example
With the default values below, Peak Water Demand Factor Calculator returns Peak Hour Flow of 31,875.00. Change any input above and every figure here is recalculated in your browser.
Inputs used
- Average Daily Demandminimum 0 m3/day
- 8,500 m3/day
- Population Servedminimum 1
- 50,000
- Maximum Day Factorminimum 1
- 1.5
- Peak Hour Factorminimum 1
- 2.5
Results
- Peak Hour Flow
- 31,875.00
- Maximum Day Flow
- 12,750.00
- Peak Hour Flow In Litres Per Second
- 368.924
- Harmon Peak Factor For This Population
- 2.2646
Step by step
- 1Values used
- 2Peak flows
- 3Harmon formula
- 4Peak Hour Flow= 31,875.00
- 5Maximum Day Flow= 12,750.00
- 6Peak Hour Flow In Litres Per Second= 368.924
- 7Harmon Peak Factor For This Population= 2.2646
Assumptions and limits
- The result is derived only from the 4 inputs listed above. Anything not among them is not part of the calculation.
- In particular, this calculator does not take inflation, tax, fees or charges or compounding frequency into account.
- Figures are rounded for display to 4 decimal places, so totals built from several rounded parts can differ slightly from the unrounded arithmetic.
How these calculators are built and tested is described on the Methodology page. If a figure looks wrong, please report it.
Frequently Asked Questions
Which flow sizes which asset?
Source and treatment are sized on maximum day, distribution mains and service reservoirs on peak hour, and pumps often on maximum day with storage absorbing the hourly peak.
Why do small systems peak more sharply?
Fewer users means less statistical smoothing of individual demand. A village of 500 can see peak hour flows four or five times average, while a city of a million rarely exceeds twice.
Related Calculators
- Water Demand For Population Calculator
- Backwash Water Volume Calculator
- Chlorine Dose For Water Calculator
- Dilution Factor For Discharge Calculator
- Grey Water Reuse Volume Calculator
- Per Capita Water Supply Calculator
- Scrubber Water Requirement Calculator
- Water Distribution Pipe Sizing Calculator
- Water Hardness Calculator
- Water Quality Index Calculator
You might also need
- Water Demand For Population CalculatorAlso in Water, Waste & Environmental Engineering
- Water Hardness CalculatorAlso in Water, Waste & Environmental Engineering
- Backwash Water Volume CalculatorAlso in Water, Waste & Environmental Engineering
- Scrubber Water Requirement CalculatorAlso in Water, Waste & Environmental Engineering
- Water Quality Index CalculatorAlso in Water, Waste & Environmental Engineering
- Water Reuse Savings CalculatorAlso in Water, Waste & Environmental Engineering