Energy Use Intensity Calculator
Work out energy use intensity instantly with clear inputs, formula shown and shareable results.
About Energy Use Intensity Calculator
Energy use intensity normalises consumption by floor area so buildings of different size can be compared. Reporting conventions differ: Europe and Asia use kilowatt hours per square metre a year, North America uses thousand Btu per square foot. A well managed office sits around 100-150 kWh/m², a poor one above 250.
Formula
Energy use intensity
kWh/m²/year = annual kWh / area in m²; kBtu/ft² = kWh/ft² x 3.412
Worked example
With the default values below, Energy Use Intensity Calculator returns Energy use intensity of 161.46. Change any input above and every figure here is recalculated in your browser.
Inputs used
- Annual electricity consumptionminimum 0 kWh
- 900,000 kWh
- Gross floor areaminimum 0.1 ft²
- 60,000 ft²
Results
- Energy use intensity
- 161.46 kWh/m²/year
- Intensity per square foot
- 15.000 kWh/ft²/year
- Intensity in kBtu
- 51.18 kBtu/ft²/year
- Average daily consumption
- 2,465.8 kWh
Step by step
- 1Values used
- 2Energy use intensity
- 3Energy use intensity= 161.46 kWh/m²/year
- 4Intensity per square foot= 15.000 kWh/ft²/year
- 5Intensity in kBtu= 51.18 kBtu/ft²/year
- 6Average daily consumption= 2,465.8 kWh
Assumptions and limits
- The result is derived only from the 2 inputs listed above. Anything not among them is not part of the calculation.
- In particular, this calculator does not take inflation, tax or fees or charges into account.
- Figures are rounded for display to 3 decimal places, so totals built from several rounded parts can differ slightly from the unrounded arithmetic.
How these calculators are built and tested is described on the Methodology page. If a figure looks wrong, please report it.
Frequently Asked Questions
How is the Energy Use Intensity figure worked out?
kWh/m²/year = annual kWh / area in m²; kBtu/ft² = kWh/ft² x 3.412. Energy use intensity normalises consumption by floor area so buildings of different size can be compared.
Should fuel be included?
Yes for a complete picture. Site EUI adds all delivered energy in common units, and source EUI further accounts for generation and transmission losses, which roughly triples the electricity component.
What values do I need to enter?
This calculator takes 2 inputs: Annual electricity consumption, Gross floor area. The pre-filled defaults are a realistic worked example — replace them with your own site or project figures.
Related Calculators
- Water Use Intensity Calculator
- Energy Rating Improvement Cost Calculator
- Absorption Rate Calculator
- Amenity Space Requirement Calculator
- Bathroom Remodel Value Calculator
- Break Even Occupancy Calculator
- Bridge Loan Cost Calculator
- Carpet To Super Built Up Ratio Calculator
- Cash Flow After Financing Calculator
- Churn Cost For Office Moves Calculator
You might also need
- Water Use Intensity CalculatorAlso in Real Estate, Property & Facilities
- Property Valuation CalculatorAlso in Real Estate, Property & Facilities
- Energy Rating Improvement Cost CalculatorAlso in Real Estate, Property & Facilities
- Absorption Rate CalculatorAlso in Real Estate, Property & Facilities
- Debt Yield CalculatorAlso in Real Estate, Property & Facilities
- Development Profit CalculatorAlso in Real Estate, Property & Facilities