Glare Index Calculator
Work out glare index instantly with clear inputs, formula shown and shareable results.
About Glare Index Calculator
The unified glare rating formula, 8 log10(0.25/Lb x sum of L² omega / p²), weights each glare source by the square of its luminance and its solid angle, divided by the square of a position index that discounts sources away from the line of sight. Office standards typically require UGR of 19 or below.
Formula
Unified glare rating
UGR = 8 log10[(0.25 / Lb) x sum(L² omega / p²)]
- Lb
- Background luminance
- L
- Source luminance
- omega
- Solid angle
- p
- Guth position index
Worked example
With the default values below, Glare Index Calculator returns Unified glare rating of 12.32. Change any input above and every figure here is recalculated in your browser.
Inputs used
- Luminance of the light sourceminimum 1 cd/m²
- 5,000 cd/m²
- Background luminanceminimum 0.1 cd/m²
- 200 cd/m²
- Solid angle of the source at the eyeminimum 0 sr
- 0.01 sr
- Guth position indexminimum 1
- 3
Results
- Unified glare rating
- 12.32
- Source to background luminance ratio
- 25.0
- Glare assessment
- Very low glare — suitable for technical drawing and precision work
- Glare summation term
- 27,777.7778
Step by step
- 1Values used
- 2Unified glare rating
- 3Unified glare rating= 12.32
- 4Source to background luminance ratio= 25.0
- 5Glare assessment= Very low glare — suitable for technical drawing and precision work
- 6Glare summation term= 27,777.7778
Assumptions and limits
- The result is derived only from the 4 inputs listed above. Anything not among them is not part of the calculation.
- In particular, this calculator does not take inflation, tax, fees or charges or compounding frequency into account.
- Figures are rounded for display to 4 decimal places, so totals built from several rounded parts can differ slightly from the unrounded arithmetic.
- Preliminary estimate only. Glare assessment for a real installation requires photometric data for the luminaires and calculation at the actual observer positions.
How these calculators are built and tested is described on the Methodology page. If a figure looks wrong, please report it.
Preliminary estimate only. Glare assessment for a real installation requires photometric data for the luminaires and calculation at the actual observer positions.
Frequently Asked Questions
How is the Glare Index figure worked out?
UGR = 8 log10[(0.25 / Lb) x sum(L² omega / p²)]. The unified glare rating formula, 8 log10(0.25/Lb x sum of L² omega / p²), weights each glare source by the square of its luminance and its solid angle, divided by the square of a position index that discounts sources away from the line of sight.
Why does background luminance appear in the denominator?
Glare is a contrast phenomenon. The same lamp is far more uncomfortable against a dark ceiling than a bright one, so raising background luminance genuinely reduces discomfort.
What values do I need to enter?
This calculator takes 4 inputs: Luminance of the light source, Background luminance, Solid angle of the source at the eye, Guth position index. The pre-filled defaults are a realistic worked example — replace them with your own site or project figures.
Related Calculators
- Lifting Index Calculator
- Mixed Exposure Index Calculator
- Accident Cost Estimate Calculator
- Air Change For Contaminant Control Calculator
- Anchor Point Load Calculator
- As Low As Reasonably Practicable Cost Calculator
- Assembly Point Area Calculator
- Audit Score For Compliance Calculator
- Bow Tie Barrier Count Calculator
- Cartridge Service Life Calculator
You might also need
- Lifting Index CalculatorAlso in Occupational Safety, Ergonomics & Risk
- Mixed Exposure Index CalculatorAlso in Occupational Safety, Ergonomics & Risk
- Exit Capacity CalculatorAlso in Occupational Safety, Ergonomics & Risk
- Ladder Angle CalculatorAlso in Occupational Safety, Ergonomics & Risk
- Rigging Capacity CalculatorAlso in Occupational Safety, Ergonomics & Risk
- Severity Rate CalculatorAlso in Occupational Safety, Ergonomics & Risk