Load Calculation For Building Calculator
Work out load calculation for building instantly with clear inputs, formula shown and shareable results.
About Load Calculation For Building Calculator
Building load starts from connected load — lighting and small power by area density plus HVAC and fixed equipment — then applies a demand factor to each category, because not everything runs simultaneously at full output. The resulting maximum demand is what sizes the supply and transformer.
Formula
Building load
connected = area x W/m2 + HVAC + equipment; maximum demand applies a factor per category
Worked example
With the default values below, Load Calculation For Building Calculator returns Total connected load of 71.25. Change any input above and every figure here is recalculated in your browser.
Inputs used
- Floor area
- 450 m²
- Lighting and small power density
- 25 W/m²
- HVAC load
- 38 kW
- Fixed equipment load
- 22 kW
Results
- Total connected load
- 71.25 kW
- Estimated maximum demand
- 55.93 kW
- Supply current at 400 V
- 89.69 A
- Overall load density
- 158.33 W/m²
Step by step
- 1Values used
- 2Building load
- 3Total connected load= 71.25 kW
- 4Estimated maximum demand= 55.93 kW
- 5Supply current at 400 V= 89.69 A
- 6Overall load density= 158.33 W/m²
Assumptions and limits
- The result is derived only from the 4 inputs listed above. Anything not among them is not part of the calculation.
- In particular, this calculator does not take inflation, tax or compounding frequency into account.
- Figures are rounded for display to 2 decimal places, so totals built from several rounded parts can differ slightly from the unrounded arithmetic.
- Electrical results are planning estimates only. Verify against the applicable wiring rules (IEC 60364, BS 7671, NEC or local code) and have all installation work designed and checked by a qualified electrician.
How these calculators are built and tested is described on the Methodology page. If a figure looks wrong, please report it.
Electrical results are planning estimates only. Verify against the applicable wiring rules (IEC 60364, BS 7671, NEC or local code) and have all installation work designed and checked by a qualified electrician.
Frequently Asked Questions
What load density is typical?
Roughly 15-25 W/m2 for offices including small power, 40-80 W/m2 for retail with display lighting, and far more for data or catering areas.
Why not just size for connected load?
It would be grossly oversized and expensive. Diversity between categories and within them is real and is recognised by every wiring code.
Related Calculators
- Motor Full Load Current Calculator
- Wire Size For Current Calculator
- 555 Timer Astable Calculator
- 555 Timer Monostable Calculator
- Amp Hours To Watt Hours Calculator
- Amplifier Gain (dB) Calculator
- Antenna Length Calculator
- Bandwidth Of A Filter Calculator
- Battery Bank Sizing Calculator
- Battery Capacity (Ah) Calculator
You might also need
- Capacitance CalculatorAlso in Electrical & Electronics
- Inductance CalculatorAlso in Electrical & Electronics
- Motor Full Load Current CalculatorAlso in Electrical & Electronics
- VSWR CalculatorAlso in Electrical & Electronics
- Wire Size For Current CalculatorAlso in Electrical & Electronics
- Amplifier Gain (dB) CalculatorAlso in Electrical & Electronics