Mine Ventilation Airflow Calculator
Work out mine ventilation airflow instantly with clear inputs, formula shown and shareable results.
About Mine Ventilation Airflow Calculator
Underground ventilation is normally governed by diesel exhaust dilution, at 0.05-0.09 m3/s per kilowatt of installed diesel power depending on jurisdiction, with a separate minimum per person. The larger requirement governs, and a leakage allowance of 20-40% is added for losses through stoppings and old workings.
Formulas
Ventilation requirement
Diesel airflow = diesel kW x statutory rate; personnel airflow = people x rate per person
Total
Total = greater of the two x (1 + leakage allowance)
Worked example
With the default values below, Mine Ventilation Airflow Calculator returns Total Airflow Required of 62.400. Change any input above and every figure here is recalculated in your browser.
Inputs used
- Diesel Equipment Power Undergroundminimum 0 kW
- 800 kW
- Airflow Per kW Of Dieselminimum 0.001 m3/s per kW
- 0.06 m3/s per kW
- Personnel Undergroundminimum 0
- 60
- Airflow Per Personminimum 0.001 m3/s
- 0.1 m3/s
Results
- Total Airflow Required
- 62.400
- Airflow For Diesel Dilution
- 48.000
- Airflow For Personnel
- 6.000
- Leakage Allowance
- 14.400
Step by step
- 1Values used
- 2Ventilation requirement
- 3Total
- 4Total Airflow Required= 62.400
- 5Airflow For Diesel Dilution= 48.000
- 6Airflow For Personnel= 6.000
- 7Leakage Allowance= 14.400
Assumptions and limits
- The result is derived only from the 4 inputs listed above. Anything not among them is not part of the calculation.
- In particular, this calculator does not take inflation, tax, fees or charges or compounding frequency into account.
- Figures are rounded for display to 3 decimal places, so totals built from several rounded parts can differ slightly from the unrounded arithmetic.
- Mine ventilation quantities are set by statute and by occupational exposure limits. Design must be certified by a competent ventilation engineer and verified by measurement and gas monitoring.
How these calculators are built and tested is described on the Methodology page. If a figure looks wrong, please report it.
Mine ventilation quantities are set by statute and by occupational exposure limits. Design must be certified by a competent ventilation engineer and verified by measurement and gas monitoring.
Frequently Asked Questions
Why is diesel dilution the governing criterion?
Diesel particulate matter and nitrogen dioxide are the most demanding contaminants to dilute to occupational exposure limits. Statutory rates per kilowatt are set specifically for that purpose.
What else must ventilation handle?
Blasting fume clearance, heat and humidity control at depth, radon where present, and dust. In deep or hot mines, cooling load rather than dilution often governs.
Related Calculators
- Mine Stripping Ratio Calculator
- Ash Content Impact Calculator
- Barrels Of Oil Equivalent Calculator
- Battery Round Trip Efficiency Calculator
- Battery Storage Sizing Calculator
- Betz Limit Power Calculator
- Biogas To Electricity Calculator
- Biomass Energy Yield Calculator
- Blasting Powder Factor Calculator
- Blending Octane Calculator
You might also need
- Mine Stripping Ratio CalculatorAlso in Energy, Oil, Gas & Mining
- Gas Bill CalculatorAlso in Energy, Oil, Gas & Mining
- Biogas To Electricity CalculatorAlso in Energy, Oil, Gas & Mining
- Blending Octane CalculatorAlso in Energy, Oil, Gas & Mining
- Capacity Factor CalculatorAlso in Energy, Oil, Gas & Mining
- Casing Depth CalculatorAlso in Energy, Oil, Gas & Mining