Shielding Half Value Layer Calculator
Work out shielding half value layer instantly with clear inputs, formula shown and shareable results.
About Shielding Half Value Layer Calculator
Shielding follows exponential attenuation, I = I0 exp(-mu.x), so the half-value layer is ln2/mu. With mu = 0.7 per cm the HVL is 0.99 cm, and 5 cm of shield is just over five HVLs, cutting the beam to 3% - an attenuation factor of 33. Exponential decay means there is no thickness that stops radiation completely.
Formulas
Exponential attenuation
I = I0 exp(-mu x)
Half-value layer
HVL = ln2 / mu
Worked example
With the default values below, Shielding Half Value Layer Calculator returns Half-Value Layer of 0.9902. Change any input above and every figure here is recalculated in your browser.
Inputs used
- Linear attenuation coefficientminimum 0 1/cm
- 0.7 1/cm
- Shield thicknessminimum 0 cm
- 5 cm
Results
- Half-Value Layer
- 0.9902 cm
- Radiation Transmitted
- 3.0197%
- Attenuation Factor
- 33.12
- Half-Value Layers Of Shielding
- 5.049
Step by step
- 1Values used
- 2Exponential attenuation
- 3Half-value layer
- 4Half-Value Layer= 0.9902 cm
- 5Radiation Transmitted= 3.0197
- 6Attenuation Factor= 33.12
- 7Half-Value Layers Of Shielding= 5.049
Assumptions and limits
- The result is derived only from the 2 inputs listed above. Anything not among them is not part of the calculation.
- In particular, this calculator does not take inflation, tax, fees or charges or compounding frequency into account.
- Figures are rounded for display to 4 decimal places, so totals built from several rounded parts can differ slightly from the unrounded arithmetic.
How these calculators are built and tested is described on the Methodology page. If a figure looks wrong, please report it.
Frequently Asked Questions
Why can radiation never be fully stopped?
Because attenuation is exponential - each layer removes a fixed fraction, not a fixed amount. Practical shielding aims for an acceptable dose rate, not zero.
What is lead's half-value layer for typical gamma rays?
About 12 mm for cobalt-60 gammas at 1.25 MeV, and only 0.1 mm for diagnostic X-rays, which is why thin lead aprons work.
Related Calculators
You might also need
- U Value CalculatorAlso in Physics - Waves, Heat, Light & Modern
- Thermal Resistance (R Value) CalculatorAlso in Physics - Waves, Heat, Light & Modern
- Redshift CalculatorAlso in Physics - Waves, Heat, Light & Modern
- Wavelength CalculatorAlso in Physics - Waves, Heat, Light & Modern
- Activity (Becquerel) CalculatorAlso in Physics - Waves, Heat, Light & Modern
- Adiabatic Process CalculatorAlso in Physics - Waves, Heat, Light & Modern