U Value Calculator
Work out u value instantly with clear inputs, formula shown and shareable results.
About U Value Calculator
U-value is the reciprocal of the total thermal resistance, counting every layer plus the internal and external surface films. Adding 2.6, 0.35 and 0.17 gives 3.12 m2 K/W and a U-value of 0.32 W/(m2 K), so each square metre loses 6.4 W under a 20 K difference.
Formulas
U-value
U = 1 / (R1 + R2 + R(surfaces))
Heat loss
Q = U x A x dT
Worked example
With the default values below, U Value Calculator returns U-Value of 0.3205. Change any input above and every figure here is recalculated in your browser.
Inputs used
- R-value of the first layerminimum 0 m2 K/W
- 2.6 m2 K/W
- R-value of the second layerminimum 0 m2 K/W
- 0.35 m2 K/W
- Combined internal and external surface resistancesminimum 0 m2 K/W
- 0.17 m2 K/W
Results
- U-Value
- 0.3205 W/(m2 K)
- Total Thermal Resistance
- 3.1200 m2 K/W
- Standard Achieved
- Older construction - upgrade worthwhile
- Heat Loss At A 20 K Difference
- 6.410 W/m2
Step by step
- 1Values used
- 2U-value
- 3Heat loss
- 4U-Value= 0.3205 W/(m2 K)
- 5Total Thermal Resistance= 3.1200 m2 K/W
- 6Standard Achieved= Older construction - upgrade worthwhile
- 7Heat Loss At A 20 K Difference= 6.410 W/m2
Assumptions and limits
- The result is derived only from the 3 inputs listed above. Anything not among them is not part of the calculation.
- In particular, this calculator does not take inflation, tax, fees or charges or compounding frequency into account.
- Figures are rounded for display to 4 decimal places, so totals built from several rounded parts can differ slightly from the unrounded arithmetic.
How these calculators are built and tested is described on the Methodology page. If a figure looks wrong, please report it.
Frequently Asked Questions
Why include surface resistances?
Because air films on both faces genuinely resist heat flow - typically 0.13 inside and 0.04 outside, which matters for thin constructions.
What U-value do new walls need?
Around 0.18 W/(m2 K) for new-build walls under current UK standards, and 0.11-0.13 for roofs.
Related Calculators
- Shielding Half Value Layer Calculator
- Thermal Resistance (R Value) Calculator
- Activity (Becquerel) Calculator
- Adiabatic Process Calculator
- Angular Resolution Calculator
- Avogadro Law Calculator
- Beat Frequency Calculator
- Binding Energy Per Nucleon Calculator
- Blackbody Radiation Calculator
- Bohr Model Energy Levels Calculator
You might also need
- Thermal Resistance (R Value) CalculatorAlso in Physics - Waves, Heat, Light & Modern
- Redshift CalculatorAlso in Physics - Waves, Heat, Light & Modern
- Wavelength CalculatorAlso in Physics - Waves, Heat, Light & Modern
- Shielding Half Value Layer CalculatorAlso in Physics - Waves, Heat, Light & Modern
- Activity (Becquerel) CalculatorAlso in Physics - Waves, Heat, Light & Modern
- Adiabatic Process CalculatorAlso in Physics - Waves, Heat, Light & Modern