Underfloor Heating Output Calculator
Work out underfloor heating output instantly with clear inputs, formula shown and shareable results.
About Underfloor Heating Output Calculator
Underfloor heating output rises with the difference between mean water temperature and room temperature, scaled by how easily the floor finish conducts heat upward. Tile passes heat well, carpet resists it. Output per square metre is capped at 175 W/m² because the floor surface temperature limit, not the water temperature, sets the practical ceiling.
Formulas
Floor output
W/m² = covering coefficient x 11 x (mean water temp - room temp), capped at 175 W/m²
Surface temperature
Surface °C = room °C + (W/m²) / 11
Worked example
With the default values below, Underfloor Heating Output Calculator returns Total floor output of 3,500. Change any input above and every figure here is recalculated in your browser.
Inputs used
- Heated floor areaminimum 1 m²
- 20 m²
- Mean water temperatureminimum 20 °C
- 40 °C
- Room design temperatureminimum 5 °C
- 21 °C
- Floor coveringone of Tile or stone, Engineered wood or laminate, Carpet with underlay
- Tile or stone
Results
- Total floor output
- 3,500 W
- Output per square metre
- 175.0 W/m²
- Water-to-room difference
- 19.0 K
- Estimated surface temperature
- 36.9 °C
Step by step
- 1Values used
- 2Floor output
- 3Surface temperature
- 4Total floor output= 3,500 W
- 5Output per square metre= 175.0 W/m²
- 6Water-to-room difference= 19.0 K
- 7Estimated surface temperature= 36.9 °C
Assumptions and limits
- The result is derived only from the 4 inputs listed above. Anything not among them is not part of the calculation.
- In particular, this calculator does not take inflation, tax, fees or charges or compounding frequency into account.
- Figures are rounded for display to 1 decimal place, so totals built from several rounded parts can differ slightly from the unrounded arithmetic.
How these calculators are built and tested is described on the Methodology page. If a figure looks wrong, please report it.
Frequently Asked Questions
How is the Underfloor Heating Output figure worked out?
W/m² = covering coefficient x 11 x (mean water temp - room temp), capped at 175 W/m². Underfloor heating output rises with the difference between mean water temperature and room temperature, scaled by how easily the floor finish conducts heat upward.
What surface temperature is acceptable?
Occupied areas are normally limited to about 29 °C and perimeter zones to 35 °C. If the calculated surface temperature exceeds that, extra emitters or better insulation are needed rather than hotter water.
What values do I need to enter?
This calculator takes 4 inputs: Heated floor area, Mean water temperature, Room design temperature, Floor covering. The pre-filled defaults are a realistic worked example — replace them with your own site or project figures.
Related Calculators
You might also need
- Extrusion Output CalculatorAlso in HVAC, Plumbing & Mechanical Trades
- Heating Load CalculatorAlso in HVAC, Plumbing & Mechanical Trades
- Bearing Life CalculatorAlso in HVAC, Plumbing & Mechanical Trades
- Belt Length CalculatorAlso in HVAC, Plumbing & Mechanical Trades
- Belt Tension CalculatorAlso in HVAC, Plumbing & Mechanical Trades
- Blower Speed CalculatorAlso in HVAC, Plumbing & Mechanical Trades