Vapour Loss Calculator
Work out vapour loss instantly with clear inputs, formula shown and shareable results.
About Vapour Loss Calculator
Tank vapour loss splits into working loss, which occurs when product is pumped in and displaces vapour, and standing loss, which is the daily breathing caused by temperature and pressure cycling. Working loss scales with throughput; standing loss scales with roof area and is what floating roofs and vapour recovery target.
Formula
Vapour loss
Working loss = throughput x working loss factor; standing loss = roof area x standing loss factor
Worked example
With the default values below, Vapour Loss Calculator returns Total Vapour Loss of 122.800. Change any input above and every figure here is recalculated in your browser.
Inputs used
- Annual Throughputminimum 0 m3
- 200,000 m3
- Working Loss Factorminimum 0 kg per m3 throughput
- 0.6 kg per m3 throughput
- Tank Roof Areaminimum 0 m2
- 700 m2
- Standing Loss Factorminimum 0 kg/m2/year
- 4 kg/m2/year
Results
- Total Vapour Loss
- 122.800
- Working Loss
- 120.000
- Standing Loss
- 2.800
- Loss As % Of Throughput
- 0.08187%
Step by step
- 1Values used
- 2Vapour loss
- 3Total Vapour Loss= 122.800
- 4Working Loss= 120.000
- 5Standing Loss= 2.800
- 6Loss As % Of Throughput= 0.08187
Assumptions and limits
- The result is derived only from the 4 inputs listed above. Anything not among them is not part of the calculation.
- In particular, this calculator does not take inflation, tax or fees or charges into account.
- Figures are rounded for display to 5 decimal places, so totals built from several rounded parts can differ slightly from the unrounded arithmetic.
- Volatile organic compound emissions from storage tanks are regulated. Use the estimation method prescribed by your air quality authority for any compliance reporting.
How these calculators are built and tested is described on the Methodology page. If a figure looks wrong, please report it.
Volatile organic compound emissions from storage tanks are regulated. Use the estimation method prescribed by your air quality authority for any compliance reporting.
Frequently Asked Questions
How are losses reduced?
Internal or external floating roofs cut standing loss by 90% or more, and vapour recovery units capture displaced vapour during filling. Both also reduce fire risk and odour complaints.
Are these losses reportable?
Yes in most jurisdictions. Volatile organic compound emissions from storage are inventoried under air quality regulation, usually using a published estimation method such as the AP-42 tank equations.
Related Calculators
- Solar Shading Loss Calculator
- Ash Content Impact Calculator
- Barrels Of Oil Equivalent Calculator
- Battery Round Trip Efficiency Calculator
- Battery Storage Sizing Calculator
- Betz Limit Power Calculator
- Biogas To Electricity Calculator
- Biomass Energy Yield Calculator
- Blasting Powder Factor Calculator
- Blending Octane Calculator
You might also need
- Solar Shading Loss CalculatorAlso in Energy, Oil, Gas & Mining
- Gas Bill CalculatorAlso in Energy, Oil, Gas & Mining
- Biogas To Electricity CalculatorAlso in Energy, Oil, Gas & Mining
- Blending Octane CalculatorAlso in Energy, Oil, Gas & Mining
- Capacity Factor CalculatorAlso in Energy, Oil, Gas & Mining
- Casing Depth CalculatorAlso in Energy, Oil, Gas & Mining