Waste To Energy Output Calculator
Work out waste to energy output instantly with clear inputs, formula shown and shareable results.
About Waste To Energy Output Calculator
Thermal input is throughput times net calorific value. Boiler efficiency of 80-86% and a steam cycle efficiency of 25-30% give gross electrical output; parasitic load for fans, pumps and flue gas treatment consumes 10-15%. Net output is typically 500-700 kWh per tonne of municipal waste.
Formulas
Thermal input
Thermal (MW) = throughput (t/h) x 1000 x CV (MJ/kg) / 3600
Electrical output
Net electrical = thermal x boiler efficiency x cycle efficiency x (1 - parasitic load)
Worked example
With the default values below, Waste To Energy Output Calculator returns Net Electrical Output of 14.3733. Change any input above and every figure here is recalculated in your browser.
Inputs used
- Waste Throughputminimum 0 tonnes/hour
- 25 tonnes/hour
- Net Calorific Valueminimum 0 MJ/kg
- 10 MJ/kg
- Boiler Efficiencyaccepts 0–100 %
- 84 %
- Steam Cycle Efficiencyaccepts 0–100 %
- 28 %
Results
- Net Electrical Output
- 14.3733
- Thermal Input
- 69.444
- Gross Electrical Output
- 16.3333
- Net Electricity Per Tonne
- 574.9
Step by step
- 1Values used
- 2Thermal input
- 3Electrical output
- 4Net Electrical Output= 14.3733
- 5Thermal Input= 69.444
- 6Gross Electrical Output= 16.3333
- 7Net Electricity Per Tonne= 574.9
Assumptions and limits
- The result is derived only from the 4 inputs listed above. Anything not among them is not part of the calculation.
- In particular, this calculator does not take inflation, tax, fees or charges or compounding frequency into account.
- Figures are rounded for display to 4 decimal places, so totals built from several rounded parts can differ slightly from the unrounded arithmetic.
- Energy from waste plants must meet emission limit values and efficiency criteria to qualify as recovery rather than disposal under waste framework legislation.
How these calculators are built and tested is described on the Methodology page. If a figure looks wrong, please report it.
Energy from waste plants must meet emission limit values and efficiency criteria to qualify as recovery rather than disposal under waste framework legislation.
Frequently Asked Questions
Why is the steam cycle efficiency so low?
Steam temperature is limited to around 400-440 C to avoid high-temperature chlorine corrosion of superheater tubes. That caps cycle efficiency well below a coal or gas plant.
Does combined heat and power help?
Substantially. Exporting heat raises total energy utilisation from under 30% to 70-85%, which is why the highest-performing plants are sited near a heat load.
Related Calculators
- Desalination Energy Requirement Calculator
- E Waste Volume Calculator
- Hazardous Waste Storage Limit Calculator
- Plastic Waste Footprint Calculator
- Sludge Dewatering Output Calculator
- Solid Waste Generation Rate Calculator
- Waste Collection Vehicle Requirement Calculator
- Waste Compaction Ratio Calculator
- Activated Carbon Dose Calculator
- Aeration Tank Volume Calculator
You might also need
- Desalination Energy Requirement CalculatorAlso in Water, Waste & Environmental Engineering
- Sludge Dewatering Output CalculatorAlso in Water, Waste & Environmental Engineering
- E Waste Volume CalculatorAlso in Water, Waste & Environmental Engineering
- BOD Load CalculatorAlso in Water, Waste & Environmental Engineering
- Chlorine Residual CalculatorAlso in Water, Waste & Environmental Engineering
- COD Load CalculatorAlso in Water, Waste & Environmental Engineering