Capacitor Charge Time Calculator
Work out capacitor charge time instantly with clear inputs, formula shown and shareable results.
About Capacitor Charge Time Calculator
An RC circuit charges exponentially: V(t) = Vs x (1 - e^(-t/RC)). One time constant reaches 63.2%, three reach 95% and five reach over 99%. Rearranging gives the time to any target voltage as -RC x ln(1 - Vt/Vs).
Formula
RC charging
V(t) = Vs (1 - e^(-t/tau)), tau = R x C; t = -tau x ln(1 - Vt/Vs)
Worked example
With the default values below, Capacitor Charge Time Calculator returns Time to reach the target of 1.39. Change any input above and every figure here is recalculated in your browser.
Inputs used
- Series resistance
- 10,000 Ω
- Capacitance
- 100 µF
- Supply voltage
- 12 V
- Target voltage
- 9 V
Results
- Time to reach the target
- 1.39 s
- Time constant
- 1.00 s
- Time to 99% (5 tau)
- 5.00 s
- Target as multiples of tau
- 1.386 x
Step by step
- 1Values used
- 2RC charging
- 3Time to reach the target= 1.39 s
- 4Time constant= 1.00 s
- 5Time to 99% (5 tau)= 5.00 s
- 6Target as multiples of tau= 1.386 x
Assumptions and limits
- The result is derived only from the 4 inputs listed above. Anything not among them is not part of the calculation.
- In particular, this calculator does not take inflation, tax, fees or charges or compounding frequency into account.
- Figures are rounded for display to 3 decimal places, so totals built from several rounded parts can differ slightly from the unrounded arithmetic.
- Electrical results are planning estimates only. Verify against the applicable wiring rules (IEC 60364, BS 7671, NEC or local code) and have all installation work designed and checked by a qualified electrician.
How these calculators are built and tested is described on the Methodology page. If a figure looks wrong, please report it.
Electrical results are planning estimates only. Verify against the applicable wiring rules (IEC 60364, BS 7671, NEC or local code) and have all installation work designed and checked by a qualified electrician.
Frequently Asked Questions
Why does it never quite finish?
The charging current is proportional to the remaining voltage difference, so it decays asymptotically. Five time constants is treated as complete in practice.
What if I need a linear ramp instead?
Use a constant-current source rather than a resistor: dV/dt = I/C gives a straight line instead of an exponential.
Related Calculators
- Capacitor Energy Calculator
- RL Time Constant Calculator
- Solar Charge Controller Sizing Calculator
- 555 Timer Astable Calculator
- 555 Timer Monostable Calculator
- Amp Hours To Watt Hours Calculator
- Amplifier Gain (dB) Calculator
- Antenna Length Calculator
- Bandwidth Of A Filter Calculator
- Battery Bank Sizing Calculator
You might also need
- Capacitor Energy CalculatorAlso in Electrical & Electronics
- RL Time Constant CalculatorAlso in Electrical & Electronics
- Capacitance CalculatorAlso in Electrical & Electronics
- Inductance CalculatorAlso in Electrical & Electronics
- VSWR CalculatorAlso in Electrical & Electronics
- Solar Charge Controller Sizing CalculatorAlso in Electrical & Electronics