Fuel Density Correction Calculator
Work out fuel density correction instantly with clear inputs, formula shown and shareable results.
About Fuel Density Correction Calculator
Petroleum expands with temperature, so density measured hot must be corrected to a reference temperature — 15 C internationally or 60 F in North America. The correction is density x (1 + alpha x temperature difference), with alpha around 0.0007 per degree for middle distillates and 0.0009 for gasoline.
Formulas
Density correction
Density at reference = observed density x (1 + alpha x (T_observed - T_reference))
API gravity
API = 141.5 / SG at 60 F - 131.5
Worked example
With the default values below, Fuel Density Correction Calculator returns Density At Reference Temperature of 855.343. Change any input above and every figure here is recalculated in your browser.
Inputs used
- Observed Densityminimum 0.01 kg/m3
- 845 kg/m3
- Observed Temperatureminimum -50 degrees C
- 32 degrees C
- Reference Temperatureminimum -50 degrees C
- 15 degrees C
- Expansion Coefficientminimum 0 per degree C
- 0.00072 per degree C
Results
- Density At Reference Temperature
- 855.343
- Volume Correction Factor
- 0.987908
- Temperature Difference
- 17.00
- API Gravity At Reference
- 33.768
Step by step
- 1Values used
- 2Density correction
- 3API gravity
- 4Density At Reference Temperature= 855.343
- 5Volume Correction Factor= 0.987908
- 6Temperature Difference= 17.00
- 7API Gravity At Reference= 33.768
Assumptions and limits
- The result is derived only from the 4 inputs listed above. Anything not among them is not part of the calculation.
- In particular, this calculator does not take inflation, tax, fees or charges or compounding frequency into account.
- Figures are rounded for display to 6 decimal places, so totals built from several rounded parts can differ slightly from the unrounded arithmetic.
- Custody transfer measurement must use the volume correction tables prescribed by the applicable measurement standard and contract.
How these calculators are built and tested is described on the Methodology page. If a figure looks wrong, please report it.
Custody transfer measurement must use the volume correction tables prescribed by the applicable measurement standard and contract.
Frequently Asked Questions
Why does custody transfer require correction?
A tanker loaded at 40 C and discharged at 15 C contains the same mass but different volume. Correcting to a standard temperature is the only way volumes can be reconciled and taxed consistently.
Which standard should be used?
The API MPMS Chapter 11 tables, or the ASTM D1250 volume correction factor tables. Simple linear expansion is adequate for estimation but not for custody transfer.
Related Calculators
- Fuel Temperature Correction Calculator
- Fuel Additive Dose Calculator
- Fuel Cell Output Calculator
- Fuel Cost Per kWh Calculator
- Nuclear Fuel Burnup Calculator
- Ash Content Impact Calculator
- Barrels Of Oil Equivalent Calculator
- Battery Round Trip Efficiency Calculator
- Battery Storage Sizing Calculator
- Betz Limit Power Calculator
You might also need
- Fuel Temperature Correction CalculatorAlso in Energy, Oil, Gas & Mining
- Fuel Additive Dose CalculatorAlso in Energy, Oil, Gas & Mining
- Fuel Cell Output CalculatorAlso in Energy, Oil, Gas & Mining
- Nuclear Fuel Burnup CalculatorAlso in Energy, Oil, Gas & Mining
- Gas Bill CalculatorAlso in Energy, Oil, Gas & Mining
- Fuel Cost Per kWh CalculatorAlso in Energy, Oil, Gas & Mining