Head And Flow For Hydro Calculator
Work out head and flow for hydro instantly with clear inputs, formula shown and shareable results.
About Head And Flow For Hydro Calculator
Rearranging the hydro power equation gives the flow needed for a target output: Q = P / (9.81 x net head x efficiency). Net head is gross head less penstock friction, which typically consumes 5-10%. Head and flow together determine the turbine type through specific speed.
Formulas
Required flow
Q (m3/s) = P (kW) / (9.81 x net head x overall efficiency)
Net head
Net head = gross head x (1 - penstock loss %)
Worked example
With the default values below, Head And Flow For Hydro Calculator returns Flow Required of 2.1726. Change any input above and every figure here is recalculated in your browser.
Inputs used
- Target Power Outputminimum 0 kW
- 500 kW
- Available Gross Headminimum 0.01 m
- 30 m
- Penstock Head Lossaccepts 0–50 %
- 8 %
- Overall Efficiencyaccepts 1–100 %
- 85 %
Results
- Flow Required
- 2.1726
- Net Head
- 27.600
- Head Lost In Penstock
- 2.400
- Indicative Turbine Type
- Francis
Step by step
- 1Values used
- 2Required flow
- 3Net head
- 4Flow Required= 2.1726
- 5Net Head= 27.600
- 6Head Lost In Penstock= 2.400
- 7Indicative Turbine Type= Francis
Assumptions and limits
- The result is derived only from the 4 inputs listed above. Anything not among them is not part of the calculation.
- In particular, this calculator does not take inflation, tax, fees or charges or compounding frequency into account.
- Figures are rounded for display to 4 decimal places, so totals built from several rounded parts can differ slightly from the unrounded arithmetic.
- Abstraction volumes, environmental flows and licence conditions govern what may actually be diverted. Confirm with the water authority before design.
How these calculators are built and tested is described on the Methodology page. If a figure looks wrong, please report it.
Abstraction volumes, environmental flows and licence conditions govern what may actually be diverted. Confirm with the water authority before design.
Frequently Asked Questions
Can the required flow always be abstracted?
No. An environmental or compensation flow must be left in the river, and abstraction is usually licensed with a hands-off flow below which no water may be taken. Design around the flow duration curve, not the peak.
How is penstock loss reduced?
Larger diameter pipe, smoother lining and fewer bends. Doubling the diameter cuts friction loss by a factor of about 32, which usually justifies the extra pipe cost on long penstocks.
Related Calculators
- Choke Size Flow Calculator
- Hydro Power Output Calculator
- Pipeline Flow Capacity Calculator
- String Sizing For Solar Calculator
- Tubing Flow Rate Calculator
- Ash Content Impact Calculator
- Barrels Of Oil Equivalent Calculator
- Battery Round Trip Efficiency Calculator
- Battery Storage Sizing Calculator
- Betz Limit Power Calculator
You might also need
- Choke Size Flow CalculatorAlso in Energy, Oil, Gas & Mining
- Hydro Power Output CalculatorAlso in Energy, Oil, Gas & Mining
- Pipeline Flow Capacity CalculatorAlso in Energy, Oil, Gas & Mining
- Tubing Flow Rate CalculatorAlso in Energy, Oil, Gas & Mining
- Gas Bill CalculatorAlso in Energy, Oil, Gas & Mining
- String Sizing For Solar CalculatorAlso in Energy, Oil, Gas & Mining