Heat Stress (WBGT) Calculator
Work out heat stress (wbgt) instantly with clear inputs, formula shown and shareable results.
About Heat Stress (WBGT) Calculator
Wet bulb globe temperature combines humidity, radiant heat and air temperature into one index. Outdoors with solar load it is 0.7 natural wet bulb plus 0.2 globe plus 0.1 dry bulb; indoors the dry bulb term drops out and the globe weighting rises. The heavy weighting on wet bulb reflects that evaporative cooling is the body's main defence.
Formulas
WBGT outdoors
WBGT = 0.7 Tnwb + 0.2 Tg + 0.1 Tdb
WBGT indoors
WBGT = 0.7 Tnwb + 0.3 Tg
Worked example
With the default values below, Heat Stress (WBGT) Calculator returns Wet bulb globe temperature of 29.10. Change any input above and every figure here is recalculated in your browser.
Inputs used
- Natural wet bulb temperatureaccepts -10–50 °C
- 27 °C
- Globe temperatureaccepts -10–80 °C
- 35 °C
- Dry bulb temperatureaccepts -10–60 °C
- 32 °C
- Exposure locationone of Outdoors with solar load, Indoors or no solar load
- Outdoors with solar load
Results
- Wet bulb globe temperature
- 29.10 °C
- Risk category
- High — work rest cycling and acclimatisation required
- Screening limit for light work
- 31.0 °C
- Recommended action
- Apply a formal work rest schedule and buddy monitoring
Step by step
- 1Values used
- 2WBGT outdoors
- 3WBGT indoors
- 4Wet bulb globe temperature= 29.10 °C
- 5Risk category= High — work rest cycling and acclimatisation required
- 6Screening limit for light work= 31.0 °C
- 7Recommended action= Apply a formal work rest schedule and buddy monitoring
Assumptions and limits
- The result is derived only from the 4 inputs listed above. Anything not among them is not part of the calculation.
- In particular, this calculator does not take inflation, tax, fees or charges or compounding frequency into account.
- Figures are rounded for display to 2 decimal places, so totals built from several rounded parts can differ slightly from the unrounded arithmetic.
- Preliminary estimate only. Heat stress assessment must follow the applicable standard, account for clothing and metabolic rate, and be supervised by a competent person.
How these calculators are built and tested is described on the Methodology page. If a figure looks wrong, please report it.
Preliminary estimate only. Heat stress assessment must follow the applicable standard, account for clothing and metabolic rate, and be supervised by a competent person.
Frequently Asked Questions
How is the Heat Stress (WBGT) figure worked out?
WBGT = 0.7 Tnwb + 0.2 Tg + 0.1 Tdb. Wet bulb globe temperature combines humidity, radiant heat and air temperature into one index.
Why not just use air temperature?
Because a humid 30 °C is far more dangerous than a dry 35 °C. Sweat cannot evaporate in high humidity, so the body loses its main cooling mechanism regardless of air temperature.
What values do I need to enter?
This calculator takes 4 inputs: Natural wet bulb temperature, Globe temperature, Dry bulb temperature, Exposure location. The pre-filled defaults are a realistic worked example — replace them with your own site or project figures.
Related Calculators
- Cold Stress Exposure Limit Calculator
- Work Rest Cycle In Heat Calculator
- Accident Cost Estimate Calculator
- Air Change For Contaminant Control Calculator
- Anchor Point Load Calculator
- As Low As Reasonably Practicable Cost Calculator
- Assembly Point Area Calculator
- Audit Score For Compliance Calculator
- Bow Tie Barrier Count Calculator
- Cartridge Service Life Calculator
You might also need
- Cold Stress Exposure Limit CalculatorAlso in Occupational Safety, Ergonomics & Risk
- Work Rest Cycle In Heat CalculatorAlso in Occupational Safety, Ergonomics & Risk
- Exit Capacity CalculatorAlso in Occupational Safety, Ergonomics & Risk
- Glare Index CalculatorAlso in Occupational Safety, Ergonomics & Risk
- Ladder Angle CalculatorAlso in Occupational Safety, Ergonomics & Risk
- Lifting Index CalculatorAlso in Occupational Safety, Ergonomics & Risk