Scrubber Efficiency Calculator
Work out scrubber efficiency instantly with clear inputs, formula shown and shareable results.
About Scrubber Efficiency Calculator
Scrubber removal efficiency is the fractional reduction in concentration between inlet and outlet. Wet limestone flue gas desulphurisation achieves 92-98%, dry sorbent injection 50-80%. Mass rates matter as much as concentration: the same efficiency on a larger gas flow still emits more pollutant.
Formulas
Removal efficiency
Efficiency % = (inlet - outlet) x 100 / inlet
Mass rate
Emitted (kg/h) = outlet concentration (mg/Nm3) x flow (Nm3/h) / 1,000,000
Worked example
With the default values below, Scrubber Efficiency Calculator returns Removal Efficiency of 92.800%. Change any input above and every figure here is recalculated in your browser.
Inputs used
- Inlet Concentrationminimum 0 mg/Nm3
- 2,500 mg/Nm3
- Outlet Concentrationminimum 0 mg/Nm3
- 180 mg/Nm3
- Flue Gas Flowminimum 0 Nm3/hour
- 1,500,000 Nm3/hour
- Permit Limitminimum 0 mg/Nm3
- 200 mg/Nm3
Results
- Removal Efficiency
- 92.800%
- Pollutant Removed Per Hour
- 3,480.00
- Pollutant Emitted Per Hour
- 270.00
- Compliance Status
- Compliant
Step by step
- 1Values used
- 2Removal efficiency
- 3Mass rate
- 4Removal Efficiency= 92.800
- 5Pollutant Removed Per Hour= 3,480.00
- 6Pollutant Emitted Per Hour= 270.00
- 7Compliance Status= Compliant
Assumptions and limits
- The result is derived only from the 4 inputs listed above. Anything not among them is not part of the calculation.
- In particular, this calculator does not take inflation, tax, fees or charges or compounding frequency into account.
- Figures are rounded for display to 3 decimal places, so totals built from several rounded parts can differ slightly from the unrounded arithmetic.
- Emission concentrations and monitoring must comply with the applicable permit, including reference oxygen correction, averaging periods and continuous monitoring requirements.
How these calculators are built and tested is described on the Methodology page. If a figure looks wrong, please report it.
Emission concentrations and monitoring must comply with the applicable permit, including reference oxygen correction, averaging periods and continuous monitoring requirements.
Frequently Asked Questions
Why do concentration limits need normalising?
Because diluting the flue gas with excess air lowers concentration without reducing emissions. Limits are set at a reference oxygen level, and measured values must be corrected to it.
What limits scrubber efficiency?
Liquid-to-gas ratio, reagent stoichiometry, residence time and absorber design. Pushing above about 98% requires disproportionate reagent and pumping energy.
Related Calculators
- Battery Round Trip Efficiency Calculator
- Combined Cycle Efficiency Calculator
- Diesel Generator Efficiency Calculator
- Pumped Storage Efficiency Calculator
- Turbine Efficiency Calculator
- Ash Content Impact Calculator
- Barrels Of Oil Equivalent Calculator
- Battery Storage Sizing Calculator
- Betz Limit Power Calculator
- Biogas To Electricity Calculator
You might also need
- Turbine Efficiency CalculatorAlso in Energy, Oil, Gas & Mining
- Combined Cycle Efficiency CalculatorAlso in Energy, Oil, Gas & Mining
- Diesel Generator Efficiency CalculatorAlso in Energy, Oil, Gas & Mining
- Pumped Storage Efficiency CalculatorAlso in Energy, Oil, Gas & Mining
- Gas Bill CalculatorAlso in Energy, Oil, Gas & Mining
- Battery Round Trip Efficiency CalculatorAlso in Energy, Oil, Gas & Mining