Separator Sizing Calculator
Work out separator sizing instantly with clear inputs, formula shown and shareable results.
About Separator Sizing Calculator
A two-phase separator must hold the liquid for long enough to release entrained gas — typically 1-3 minutes for oil, longer for foaming or viscous crude. Holdup volume is liquid rate converted to cubic feet per minute times retention time; the vessel is then sized with a length-to-diameter ratio of about 3 to 4.
Formulas
Liquid holdup
Holdup volume (ft3) = liquid rate (bbl/d) x 5.6146 / 1440 x retention time (min)
Vessel geometry
Size the shell for the holdup volume at a length-to-diameter ratio of 3 to 4
Worked example
With the default values below, Separator Sizing Calculator returns Required Liquid Holdup Volume of 58.485. Change any input above and every figure here is recalculated in your browser.
Inputs used
- Liquid Rateminimum 0 bbl/day
- 5,000 bbl/day
- Gas Rateminimum 0 MMscf/day
- 8 MMscf/day
- Liquid Retention Timeminimum 0.01 minutes
- 3 minutes
- Operating Pressureminimum 0.01 psig
- 250 psig
Results
- Required Liquid Holdup Volume
- 58.485
- Indicative Vessel Diameter
- 5.834
- Indicative Vessel Length
- 17.502
- Gas Volumetric Rate
- 5.1421
Step by step
- 1Values used
- 2Liquid holdup
- 3Vessel geometry
- 4Required Liquid Holdup Volume= 58.485
- 5Indicative Vessel Diameter= 5.834
- 6Indicative Vessel Length= 17.502
- 7Gas Volumetric Rate= 5.1421
Assumptions and limits
- The result is derived only from the 4 inputs listed above. Anything not among them is not part of the calculation.
- In particular, this calculator does not take inflation, tax, fees or charges or compounding frequency into account.
- Figures are rounded for display to 4 decimal places, so totals built from several rounded parts can differ slightly from the unrounded arithmetic.
- Pressure vessel design, sizing and relief protection must comply with the applicable pressure vessel code and be certified by a qualified engineer.
How these calculators are built and tested is described on the Methodology page. If a figure looks wrong, please report it.
Pressure vessel design, sizing and relief protection must comply with the applicable pressure vessel code and be certified by a qualified engineer.
Frequently Asked Questions
What sets the gas capacity of a separator?
The Souders-Brown droplet settling criterion, which limits gas velocity so that liquid droplets fall out rather than being carried over. It scales with the square root of the density difference.
Why do foaming crudes need larger separators?
Foam occupies vessel volume without separating, so retention time must be multiplied — often by two to four — or a foam-breaking internal fitted.
Related Calculators
- Battery Storage Sizing Calculator
- Dewatering Pump Sizing Calculator
- Electrolyser Sizing Calculator
- Solar Inverter Sizing Calculator
- String Sizing For Solar Calculator
- Ash Content Impact Calculator
- Barrels Of Oil Equivalent Calculator
- Battery Round Trip Efficiency Calculator
- Betz Limit Power Calculator
- Biogas To Electricity Calculator
You might also need
- Electrolyser Sizing CalculatorAlso in Energy, Oil, Gas & Mining
- Battery Storage Sizing CalculatorAlso in Energy, Oil, Gas & Mining
- Dewatering Pump Sizing CalculatorAlso in Energy, Oil, Gas & Mining
- Solar Inverter Sizing CalculatorAlso in Energy, Oil, Gas & Mining
- Gas Bill CalculatorAlso in Energy, Oil, Gas & Mining
- String Sizing For Solar CalculatorAlso in Energy, Oil, Gas & Mining