Submersible Pump Selection Calculator
Work out submersible pump selection instantly with clear inputs, formula shown and shareable results.
About Submersible Pump Selection Calculator
A submersible pump must lift water from the pumping level, not the static level, so drawdown at design flow is added first. On top of that come the rise to the storage tank, the tank pressure converted at 2.31 feet per psi, and a friction allowance. Each stage of a typical four-inch submersible develops roughly 25 feet of head.
Formulas
Total dynamic head
TDH = static level + drawdown + surface rise + psi x 2.307 + friction
Stage count
Stages = TDH / head per stage (about 25 ft for a 4 in submersible)
Worked example
With the default values below, Submersible Pump Selection Calculator returns Total dynamic head of 260.3. Change any input above and every figure here is recalculated in your browser.
Inputs used
- Static water level below grademinimum 0 ft
- 120 ft
- Drawdown at design flowminimum 0 ft
- 25 ft
- Rise from wellhead to tankminimum 0 ft
- 15 ft
- Pressure required at tankminimum 0 psi
- 40 psi
Results
- Total dynamic head
- 260.3 ft
- Pumping water level
- 145.0 ft
- Head from tank pressure
- 92.3 ft
- Approximate stages needed
- 11
Step by step
- 1Values used
- 2Total dynamic head
- 3Stage count
- 4Total dynamic head= 260.3 ft
- 5Pumping water level= 145.0 ft
- 6Head from tank pressure= 92.3 ft
- 7Approximate stages needed= 11
Assumptions and limits
- The result is derived only from the 4 inputs listed above. Anything not among them is not part of the calculation.
- In particular, this calculator does not take inflation, tax, fees or charges or compounding frequency into account.
- Figures are rounded for display to 1 decimal place, so totals built from several rounded parts can differ slightly from the unrounded arithmetic.
How these calculators are built and tested is described on the Methodology page. If a figure looks wrong, please report it.
Frequently Asked Questions
How is the Submersible Pump Selection figure worked out?
TDH = static level + drawdown + surface rise + psi x 2.307 + friction. A submersible pump must lift water from the pumping level, not the static level, so drawdown at design flow is added first.
Why does drawdown matter so much?
In a low-yielding well drawdown can exceed the static depth, doubling the head. Sizing on static level alone leaves the pump unable to deliver its rated flow.
What values do I need to enter?
This calculator takes 4 inputs: Static water level below grade, Drawdown at design flow, Rise from wellhead to tank, Pressure required at tank. The pre-filled defaults are a realistic worked example — replace them with your own site or project figures.
Related Calculators
- Booster Pump Pressure Calculator
- Hydraulic Pump Flow Calculator
- Irrigation Pump Sizing Calculator
- Pump Sizing For Water Supply Calculator
- Air Changes Per Hour Calculator
- Air Compressor Sizing Calculator
- Air Conditioner Sizing Calculator
- Air Receiver Tank Size Calculator
- Bearing Life Calculator
- Bearing Load Rating Calculator
You might also need
- Booster Pump Pressure CalculatorAlso in HVAC, Plumbing & Mechanical Trades
- Hydraulic Pump Flow CalculatorAlso in HVAC, Plumbing & Mechanical Trades
- Irrigation Pump Sizing CalculatorAlso in HVAC, Plumbing & Mechanical Trades
- Bearing Life CalculatorAlso in HVAC, Plumbing & Mechanical Trades
- Belt Length CalculatorAlso in HVAC, Plumbing & Mechanical Trades
- Belt Tension CalculatorAlso in HVAC, Plumbing & Mechanical Trades