Zener Diode Resistor Calculator
Work out zener diode resistor instantly with clear inputs, formula shown and shareable results.
About Zener Diode Resistor Calculator
The series resistor must pass the load current plus a minimum zener current: R = (Vin - Vz)/(IL + IZmin). The worst case for the zener is no load, when it carries the entire current, so its power rating must cover Vz times the full current.
Formula
Zener shunt regulator
R = (Vin - Vz) / (Iload + Izmin); Pzener(worst case) = Vz x (Vin - Vz) / R
Worked example
With the default values below, Zener Diode Resistor Calculator returns Series resistor of 276.00. Change any input above and every figure here is recalculated in your browser.
Inputs used
- Input voltage
- 12 V
- Zener voltage
- 5.1 V
- Load current
- 20 mA
- Minimum zener current
- 5 mA
Results
- Series resistor
- 276.00 Ω
- Resistor dissipation
- 172.50 mW
- Zener dissipation at no load
- 127.50 mW
- Nearest E24 resistor
- 270.00 Ω
Step by step
- 1Values used
- 2Zener shunt regulator
- 3Series resistor= 276.00 Ω
- 4Resistor dissipation= 172.50 mW
- 5Zener dissipation at no load= 127.50 mW
- 6Nearest E24 resistor= 270.00 Ω
Assumptions and limits
- The result is derived only from the 4 inputs listed above. Anything not among them is not part of the calculation.
- In particular, this calculator does not take inflation, tax or compounding frequency into account.
- Figures are rounded for display to 2 decimal places, so totals built from several rounded parts can differ slightly from the unrounded arithmetic.
- Electrical results are planning estimates only. Verify against the applicable wiring rules (IEC 60364, BS 7671, NEC or local code) and have all installation work designed and checked by a qualified electrician.
How these calculators are built and tested is described on the Methodology page. If a figure looks wrong, please report it.
Electrical results are planning estimates only. Verify against the applicable wiring rules (IEC 60364, BS 7671, NEC or local code) and have all installation work designed and checked by a qualified electrician.
Frequently Asked Questions
Why is no load the worst case?
Because the resistor current is fixed by the input voltage, so with the load disconnected all of it flows through the zener.
When should I use a proper regulator instead?
Whenever load current varies much or efficiency matters. A shunt zener wastes the full current continuously and regulates poorly.
Related Calculators
- Diode Forward Voltage Drop Calculator
- Resistor Colour Code Calculator
- Resistor Value To Colour Code Calculator
- Shunt Resistor Calculator
- SMD Resistor Code Calculator
- 555 Timer Astable Calculator
- 555 Timer Monostable Calculator
- Amp Hours To Watt Hours Calculator
- Amplifier Gain (dB) Calculator
- Antenna Length Calculator
You might also need
- Shunt Resistor CalculatorAlso in Electrical & Electronics
- Resistor Colour Code CalculatorAlso in Electrical & Electronics
- SMD Resistor Code CalculatorAlso in Electrical & Electronics
- Capacitance CalculatorAlso in Electrical & Electronics
- Inductance CalculatorAlso in Electrical & Electronics
- VSWR CalculatorAlso in Electrical & Electronics